dorsal/arxiv
View SchemaLuminosity, Energy and Polarization Studies for the Linear Collider: Comparing e+e- and e-e- for NLC and TESLA
| Authors | M. Woods, A. Florimonte, K. C. Moffeit, T. O. Raubenheimer, A. Seryi, C. Sramek |
|---|---|
| Categories | |
| ArXiv ID | physics/0403037 |
| URL | https://arxiv.org/abs/physics/0403037 |
| DOI | 10.1142/S0217751X05031241 |
Abstract
We present results from luminosity, energy and polarization studies at a future Linear Collider. We compare e+e- and e-e- modes of operation and consider both NLC and TESLA beam parameter specifications at a center-of-mass energy of 500 GeV. Realistic colliding beam distributions are used, which include dynamic effects of the beam transport from the Damping Rings to the Interaction Point. Beam-beam deflections scans and their impact for beam-based feedbacks are considered. A transverse kink instability is studied, including its impact on determining the luminosity-weighted center-of-mass energy. Polarimetry in the extraction line from the IP is presented, including results on beam distributions at the Compton IP and at the Compton detector.
{
"annotation_id": "f493b3a2-157f-419a-97dd-bc85a8358ade",
"date_created": "2026-03-02T18:00:50.497000Z",
"date_modified": "2026-03-02T18:00:50.497000Z",
"file_hash": "ec9c6a3e72db9d9548b6edc6d2f2168420ca303b760fba0dcf645fb9ee48390a",
"private": false,
"record": {
"abstract": "We present results from luminosity, energy and polarization studies at a\nfuture Linear Collider. We compare e+e- and e-e- modes of operation and\nconsider both NLC and TESLA beam parameter specifications at a center-of-mass\nenergy of 500 GeV. Realistic colliding beam distributions are used, which\ninclude dynamic effects of the beam transport from the Damping Rings to the\nInteraction Point. Beam-beam deflections scans and their impact for beam-based\nfeedbacks are considered. A transverse kink instability is studied, including\nits impact on determining the luminosity-weighted center-of-mass energy.\nPolarimetry in the extraction line from the IP is presented, including results\non beam distributions at the Compton IP and at the Compton detector.",
"arxiv_id": "physics/0403037",
"authors": [
"M. Woods",
"A. Florimonte",
"K. C. Moffeit",
"T. O. Raubenheimer",
"A. Seryi",
"C. Sramek"
],
"categories": [
"physics.acc-ph"
],
"doi": "10.1142/S0217751X05031241",
"title": "Luminosity, Energy and Polarization Studies for the Linear Collider: Comparing e+e- and e-e- for NLC and TESLA",
"url": "https://arxiv.org/abs/physics/0403037"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "1aa3d33b-faa3-4790-84c3-0159f7aa2214",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}