dorsal/arxiv
View SchemaMeasurement of the electron electric dipole moment using GdIG
| Authors | B. J. Heidenreich, O. T. Elliott, N. D. Charney, K. A. Virgien, A. W. Bridges, M. A. McKeon, S. K. Peck, D. Krause, Jr., J. E. Gordon, L. R. Hunter, S. K. Lamoreaux |
|---|---|
| Categories | |
| ArXiv ID | physics/0509106 |
| URL | https://arxiv.org/abs/physics/0509106 |
| DOI | 10.1103/PhysRevLett.95.253004 |
| Journal | Phys.Rev.Lett. 95 (2005) 253004 |
Abstract
A new method for the detection of the electron edm using a solid is described. The method involves the measurement of a voltage induced across the solid by the alignment of the samples magnetic dipoles in an applied magnetic field, H. A first application of the method to GdIG has resulted in a limit on the electron edm of 5E-24 e-cm, which is a factor of 40 below the limit obtained from the only previous solid-state edm experiment. The result is limited by the imperfect discrimination of an unexpectedly large voltage that is even upon the reversal of the sample magnetization.
{
"annotation_id": "e6e062de-3791-4ca3-9963-24c4b7d52035",
"date_created": "2026-03-02T18:00:59.935000Z",
"date_modified": "2026-03-02T18:00:59.935000Z",
"file_hash": "ec9abcdafb0c50c48562f86dca0adfea468733ac5b4138fb47a6b5e11723f823",
"private": false,
"record": {
"abstract": "A new method for the detection of the electron edm using a solid is\ndescribed. The method involves the measurement of a voltage induced across the\nsolid by the alignment of the samples magnetic dipoles in an applied magnetic\nfield, H. A first application of the method to GdIG has resulted in a limit on\nthe electron edm of 5E-24 e-cm, which is a factor of 40 below the limit\nobtained from the only previous solid-state edm experiment. The result is\nlimited by the imperfect discrimination of an unexpectedly large voltage that\nis even upon the reversal of the sample magnetization.",
"arxiv_id": "physics/0509106",
"authors": [
"B. J. Heidenreich",
"O. T. Elliott",
"N. D. Charney",
"K. A. Virgien",
"A. W. Bridges",
"M. A. McKeon",
"S. K. Peck",
"D. Krause, Jr.",
"J. E. Gordon",
"L. R. Hunter",
"S. K. Lamoreaux"
],
"categories": [
"physics.atom-ph",
"cond-mat.other",
"hep-ph"
],
"doi": "10.1103/PhysRevLett.95.253004",
"journal_ref": "Phys.Rev.Lett. 95 (2005) 253004",
"title": "Measurement of the electron electric dipole moment using GdIG",
"url": "https://arxiv.org/abs/physics/0509106"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "6d77633b-51ec-490b-aa86-da96e9e856f5",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}