Abstract
In this paper we describe the operation and performance of the HERA-B Outer Tracker, a 112674 channel system of planar drift tube layers. The performance of the HERA-B Outer Tracker system fullfilled all requirements for stable and efficient operation in a hadronic environment, thus confirming the adequacy of the honeycomb drift tube technology and of the front-end readout system. The detector was stably operated with a gas gain of 30000 in an Ar/CF4/CO2 (65:30:5) gas mixture, yielding a good efficiency for triggering and track reconstruction, larger than 95 % for tracks with momenta above 5 GeV/c. The hit resolution of the drift cells was 300 to 320 micrometers and the relative momentum resolution can be described as: sigma(p)/p (in %) = (1.61 +- 0.02) + (0.0051 +- 0.0006) p. At the end of the HERA-B running no aging effects in the Outer Tracker cells were observed.
{
"annotation_id": "e21a7f72-e937-4341-a363-c66dbbcfc228",
"date_created": "2026-03-02T18:01:17.182000Z",
"date_modified": "2026-03-02T18:01:17.182000Z",
"file_hash": "9399f2704610b6e760720894c43e07d2d3c5917b7f292ff11a9e8b5282227e04",
"private": false,
"record": {
"abstract": "In this paper we describe the operation and performance of the HERA-B Outer\nTracker, a 112674 channel system of planar drift tube layers. The performance\nof the HERA-B Outer Tracker system fullfilled all requirements for stable and\nefficient operation in a hadronic environment, thus confirming the adequacy of\nthe honeycomb drift tube technology and of the front-end readout system. The\ndetector was stably operated with a gas gain of 30000 in an Ar/CF4/CO2\n(65:30:5) gas mixture, yielding a good efficiency for triggering and track\nreconstruction, larger than 95 % for tracks with momenta above 5 GeV/c. The hit\nresolution of the drift cells was 300 to 320 micrometers and the relative\nmomentum resolution can be described as: sigma(p)/p (in %) = (1.61 +- 0.02) +\n(0.0051 +- 0.0006) p. At the end of the HERA-B running no aging effects in the\nOuter Tracker cells were observed.",
"arxiv_id": "physics/0701122",
"authors": [
"H. Albrecht"
],
"categories": [
"physics.ins-det"
],
"doi": "10.1016/j.nima.2007.03.025",
"journal_ref": "Nucl.Instrum.Meth.A576:312-330,2007",
"title": "The Outer Tracker Detector of the HERA-B Experiment. Part III: Operation and Performance",
"url": "https://arxiv.org/abs/physics/0701122"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "b27943e5-cd8f-4761-b2c8-c4195975999a",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}