dorsal/arxiv
View SchemaSuppression of Spin Projection Noise in Broadband Atomic Magnetometry
| Authors | J. M. Geremia, John K. Stockton, Hideo Mabuchi |
|---|---|
| Categories | |
| ArXiv ID | quant-ph/0401107 |
| URL | https://arxiv.org/abs/quant-ph/0401107 |
| DOI | 10.1103/PhysRevLett.94.203002 |
| License | http://arxiv.org/licenses/nonexclusive-distrib/1.0/ |
Abstract
Our 2005 Physical Review Letter entitled "Suppression of Spin-Projection Noise in Broadband Atomic Magnetometry" (volume 94, 203002) relied heavily in its claims of experimental quantum-limited performance on the results of a prior publication from our group [1]. In subsequent work we have determined that the results of [1] were incorrect and must therefore retract this Physical Review Letter as well. The authors would like to emphasize that the broadband magnetometry approach taken in our work remains valid, as described in the theoretical paper [2], but we have lost confidence in the calibration procedures employed at the time to establish sensitivity relative to the spin-projection noise level. [1] JM Geremia, John K. Stockton and Hideo Mabuchi, "Real-Time Quantum Feedback Control of Atomic Spin-Squeezing," Science 304, 270, (2004). [2] John K. Stockton, JM Geremia, Andrew C. Doherty and Hideo Mabuchi, "Robust quantum parameter estimation: Coherent magnetometry with feedback," Phys. Rev. A 69, 032109, (2004).
{
"annotation_id": "de14bd64-1829-4c8f-be79-63a2a961d4f2",
"date_created": "2026-03-02T18:02:05.748000Z",
"date_modified": "2026-03-02T18:02:05.748000Z",
"file_hash": "e04a401bdfef2b56527c74b29dc2de72735b0b542f53f438543318123c1a4ec9",
"private": false,
"record": {
"abstract": "Our 2005 Physical Review Letter entitled \"Suppression of Spin-Projection\nNoise in Broadband Atomic Magnetometry\" (volume 94, 203002) relied heavily in\nits claims of experimental quantum-limited performance on the results of a\nprior publication from our group [1]. In subsequent work we have determined\nthat the results of [1] were incorrect and must therefore retract this Physical\nReview Letter as well. The authors would like to emphasize that the broadband\nmagnetometry approach taken in our work remains valid, as described in the\ntheoretical paper [2], but we have lost confidence in the calibration\nprocedures employed at the time to establish sensitivity relative to the\nspin-projection noise level.\n [1] JM Geremia, John K. Stockton and Hideo Mabuchi, \"Real-Time Quantum\nFeedback Control of Atomic Spin-Squeezing,\" Science 304, 270, (2004).\n [2] John K. Stockton, JM Geremia, Andrew C. Doherty and Hideo Mabuchi,\n\"Robust quantum parameter estimation: Coherent magnetometry with feedback,\"\nPhys. Rev. A 69, 032109, (2004).",
"arxiv_id": "quant-ph/0401107",
"authors": [
"J. M. Geremia",
"John K. Stockton",
"Hideo Mabuchi"
],
"categories": [
"quant-ph"
],
"doi": "10.1103/PhysRevLett.94.203002",
"license": "http://arxiv.org/licenses/nonexclusive-distrib/1.0/",
"title": "Suppression of Spin Projection Noise in Broadband Atomic Magnetometry",
"url": "https://arxiv.org/abs/quant-ph/0401107"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "11c0add0-bedd-4848-b0ef-d0b139ae8173",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}