Abstract
We present a scheme for a photon-counting detection system that can be operated at incident photon rates higher than otherwise possible by suppressing the effects of detector deadtime. The method uses an array of N detectors and a 1-by-N optical switch with a control circuit to direct input light to live detectors. Our calculations and models highlight the advantages of the technique. In particular, using this scheme, a group of N detectors provides an improvement in operation rate that can exceed the improvement that would be obtained by a single detector with deadtime reduced by 1/N, even if it were feasible to produce a single detector with such a large improvement in deadtime. We model the system for continuous and pulsed light sources, both of which are important for quantum metrology and quantum key distribution applications.
{
"annotation_id": "ba96f06e-e0e3-4342-8e39-e85b0fe19588",
"date_created": "2026-03-02T18:02:24.141000Z",
"date_modified": "2026-03-02T18:02:24.141000Z",
"file_hash": "a7f6044d768f8307f666eb142a5e359f775db53e73b48d2cd9d57a1b784615e3",
"private": false,
"record": {
"abstract": "We present a scheme for a photon-counting detection system that can be\noperated at incident photon rates higher than otherwise possible by suppressing\nthe effects of detector deadtime. The method uses an array of N detectors and a\n1-by-N optical switch with a control circuit to direct input light to live\ndetectors. Our calculations and models highlight the advantages of the\ntechnique. In particular, using this scheme, a group of N detectors provides an\nimprovement in operation rate that can exceed the improvement that would be\nobtained by a single detector with deadtime reduced by 1/N, even if it were\nfeasible to produce a single detector with such a large improvement in\ndeadtime. We model the system for continuous and pulsed light sources, both of\nwhich are important for quantum metrology and quantum key distribution\napplications.",
"arxiv_id": "quant-ph/0601102",
"authors": [
"S. Castelletto",
"I. P. Degiovanni",
"V. Schettini",
"A. Migdall"
],
"categories": [
"quant-ph"
],
"doi": "10.1080/09500340600779579",
"title": "Reduced Deadtime and Higher Rate Photon-Counting Detection using a Multiplexed Detector Array",
"url": "https://arxiv.org/abs/quant-ph/0601102"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "564a7aec-81d1-4a72-b8bc-1e02132efe95",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}