dorsal/arxiv
View SchemaVirtual model of the differential pulse reversible calorimeter
| Authors | G. Tvauri, N. Bakradze, E. Kiziria |
|---|---|
| Categories | |
| ArXiv ID | physics/0401167 |
| URL | https://arxiv.org/abs/physics/0401167 |
Abstract
A new method of absolute heat capacity measurement was developed in the Department of Biological Systems Physics at the E. Andronikashvili Institute of Physics, Georgian Academy of Sciences. This is the method of absolute heat capacity measurement of the differential calorimetric ampoule sample and reference cells and the adiabatic shell temperature difference registration while stepwise alteration of temperature (increase or decrease) of system occurs. The new method makes possible to determine both the heat capacities of the sample and reference cells and their difference. The method of cell temperature difference compensation is used in order to decrease in the time of equilibrium establishment. The proposed method of absolute heat capacity measurement was implemented in the model of the virtual differential pulse reversible calorimeter.
{
"annotation_id": "5d6370db-9350-4ba1-8e2c-62e4e101efc1",
"date_created": "2026-03-02T18:00:49.576000Z",
"date_modified": "2026-03-02T18:00:49.576000Z",
"file_hash": "e01c8eef68b79804b09888624581e4be5975e490f0dfabc9e64d1eb150abfe56",
"private": false,
"record": {
"abstract": "A new method of absolute heat capacity measurement was developed in the\nDepartment of Biological Systems Physics at the E. Andronikashvili Institute of\nPhysics, Georgian Academy of Sciences. This is the method of absolute heat\ncapacity measurement of the differential calorimetric ampoule sample and\nreference cells and the adiabatic shell temperature difference registration\nwhile stepwise alteration of temperature (increase or decrease) of system\noccurs. The new method makes possible to determine both the heat capacities of\nthe sample and reference cells and their difference. The method of cell\ntemperature difference compensation is used in order to decrease in the time of\nequilibrium establishment. The proposed method of absolute heat capacity\nmeasurement was implemented in the model of the virtual differential pulse\nreversible calorimeter.",
"arxiv_id": "physics/0401167",
"authors": [
"G. Tvauri",
"N. Bakradze",
"E. Kiziria"
],
"categories": [
"physics.bio-ph",
"physics.ins-det"
],
"title": "Virtual model of the differential pulse reversible calorimeter",
"url": "https://arxiv.org/abs/physics/0401167"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "96657f59-2342-45b3-b4b5-a78134761c6b",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}