View SchemaStudies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays
| Authors | H. Sekiya, K. Hattori, H. Kubo, K. Miuchi, T. Nagayoshi, H. Nishimura, Y. Okada, R. Orito, A. Takada, A. Takeda, T. Tanimori, K. Ueno |
|---|---|
| Categories | |
| ArXiv ID | physics/0510221 |
| URL | https://arxiv.org/abs/physics/0510221 |
| DOI | 10.1016/j.nima.2006.01.096 |
Abstract
We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\times6\times20{\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of $^{137}$Cs. We also investigated the energy resolution of these systems and showed the performance of the cascade connection of resistive network between some PMTs for large area detectors.
{
"annotation_id": "288bb1d8-a3ce-40c7-a6b4-0d1af45b5a00",
"date_created": "2026-03-02T18:01:03.086000Z",
"date_modified": "2026-03-02T18:01:03.086000Z",
"file_hash": "997aae398a7a53e8d2765f331f4f5195199844058258237753c14c722f257de5",
"private": false,
"record": {
"abstract": "We have studied the performance of two different types of front-end systems\nfor our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels\nmulti-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64\npixels of $6\\times6\\times20{\\rm mm}^3$ which corresponds to the anode pixels of\nH8500. One of the system is based on commercial ASIC chips in order to readout\nevery anode. The others are based on resistive charge divider network between\nanodes to reduce readout channels. In both systems, each pixel (6mm) was\nclearly resolved by flood field irradiation of $^{137}$Cs. We also investigated\nthe energy resolution of these systems and showed the performance of the\ncascade connection of resistive network between some PMTs for large area\ndetectors.",
"arxiv_id": "physics/0510221",
"authors": [
"H. Sekiya",
"K. Hattori",
"H. Kubo",
"K. Miuchi",
"T. Nagayoshi",
"H. Nishimura",
"Y. Okada",
"R. Orito",
"A. Takada",
"A. Takeda",
"T. Tanimori",
"K. Ueno"
],
"categories": [
"physics.ins-det"
],
"doi": "10.1016/j.nima.2006.01.096",
"title": "Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays",
"url": "https://arxiv.org/abs/physics/0510221"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "b4368d5e-172c-4d8d-9548-76a88e4db137",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}