dorsal/arxiv
View SchemaOptical response of a misaligned and suspended Fabry-Perot cavity
| Authors | G. Cella, A. Di Virgilio, P. La Penna, V. D'Auria, A. Porzio, I. Ricciardi, S. Solimeno |
|---|---|
| Categories | |
| ArXiv ID | quant-ph/0512252 |
| URL | https://arxiv.org/abs/quant-ph/0512252 |
| DOI | 10.1103/PhysRevA.74.013814 |
| Journal | Phys. Rev. A 74:380114 (2006) |
Abstract
The response to a probe laser beam of a suspended, misaligned and detuned optical cavity is examined. A five degree of freedom model of the fluctuations of the longitudinal and transverse mirror coordinates is presented. Classical and quantum mechanical effects of radiation pressure are studied with the help of the optical stiffness coefficients and the signals provided by an FM sideband technique and a quadrant detector, for generic values of the product $\varpi \tau $ of the fluctuation frequency times the cavity round trip. A simplified version is presented for the case of small misalignments. Mechanical stability, mirror position entanglement and ponderomotive squeezing are accommodated in this model. Numerical plots refer to cavities under test at the so-called Pisa LF facility.
{
"annotation_id": "26383baa-71c1-46ad-82af-fda02ec21baf",
"date_created": "2026-03-02T18:02:24.206000Z",
"date_modified": "2026-03-02T18:02:24.206000Z",
"file_hash": "1d2aa4d927a52f3d8b1cf3aab209194276905fcef4883bcdd55a035053b393e8",
"private": false,
"record": {
"abstract": "The response to a probe laser beam of a suspended, misaligned and detuned\noptical cavity is examined. A five degree of freedom model of the fluctuations\nof the longitudinal and transverse mirror coordinates is presented. Classical\nand quantum mechanical effects of radiation pressure are studied with the help\nof the optical stiffness coefficients and the signals provided by an FM\nsideband technique and a quadrant detector, for generic values of the product\n$\\varpi \\tau $ of the fluctuation frequency times the cavity round trip. A\nsimplified version is presented for the case of small misalignments. Mechanical\nstability, mirror position entanglement and ponderomotive squeezing are\naccommodated in this model. Numerical plots refer to cavities under test at the\nso-called Pisa LF facility.",
"arxiv_id": "quant-ph/0512252",
"authors": [
"G. Cella",
"A. Di Virgilio",
"P. La Penna",
"V. D\u0027Auria",
"A. Porzio",
"I. Ricciardi",
"S. Solimeno"
],
"categories": [
"quant-ph"
],
"doi": "10.1103/PhysRevA.74.013814",
"journal_ref": "Phys. Rev. A 74:380114 (2006)",
"title": "Optical response of a misaligned and suspended Fabry-Perot cavity",
"url": "https://arxiv.org/abs/quant-ph/0512252"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "12d5adb3-56dd-49ba-947e-c5efa08e5d48",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}