dorsal/arxiv
View SchemaDAFNE injection system upgrade
| Authors | A. Ghigo |
|---|---|
| Categories | |
| ArXiv ID | physics/0404010 |
| URL | https://arxiv.org/abs/physics/0404010 |
Abstract
High luminosity in DAFNE needs very high electron and positron currents stored. A full energy (510 MeV) injection system composed by a full energy electron and positron linac and an accumulator-damping ring is presently used. The electron and positron beams, alternatively accelerated by the linac, are injected and stacked in the accumulator with high efficiency thanks to its large acceptance and short damping time. The damped beams are extracted and transferred to the main ring through a long transfer line that has been built inside already existing buildings. The refill time of the collider is limited by the transfer line set-up change between the two different beams modes. In this paper a transfer line modification is proposed in order to reduce the switch time. A possible injection scheme for the main rings is also described.
{
"annotation_id": "213335eb-c510-439e-97c6-d67775135fc3",
"date_created": "2026-03-02T18:00:49.388000Z",
"date_modified": "2026-03-02T18:00:49.388000Z",
"file_hash": "bfb9106d68c8742ac998b8a688d55dd0b6ac2b63b58488cea3412dea4e885788",
"private": false,
"record": {
"abstract": "High luminosity in DAFNE needs very high electron and positron currents\nstored. A full energy (510 MeV) injection system composed by a full energy\nelectron and positron linac and an accumulator-damping ring is presently used.\nThe electron and positron beams, alternatively accelerated by the linac, are\ninjected and stacked in the accumulator with high efficiency thanks to its\nlarge acceptance and short damping time. The damped beams are extracted and\ntransferred to the main ring through a long transfer line that has been built\ninside already existing buildings. The refill time of the collider is limited\nby the transfer line set-up change between the two different beams modes. In\nthis paper a transfer line modification is proposed in order to reduce the\nswitch time. A possible injection scheme for the main rings is also described.",
"arxiv_id": "physics/0404010",
"authors": [
"A. Ghigo"
],
"categories": [
"physics.acc-ph"
],
"title": "DAFNE injection system upgrade",
"url": "https://arxiv.org/abs/physics/0404010"
},
"schema_id": "dorsal/arxiv",
"source": {
"execution_id": "f52100f0-2746-408f-b8b8-f081b26c6fb2",
"id": "arXiv Dataset IDs",
"type": "Model",
"variant": "snapshot-2026-03-01",
"version": "0.1.0"
},
"user_id": 1000002
}